Categories

Instronix Process Controls

ADDMAS Thermal Mass Flowmeters

₹ 65000.00  Incl. GST ₹ 55084.75 Excl. GST

Description

ADDMAS Thermal Mass Flowmeters

Minimum Order Quantity: 1
1 Pack contains : 1 Unit

 

At Thermal Mass Flowmeter is one of the most advanced flowmeters in gas mass monitoring. The sensor of AT Thermal Mass Flowmeter is related to flow rate of the gas mass and meet the situation which the temperature and pressure are unstable Thermal sensor consists of two sensing elements - a velocity sensor and a temperature sensor that automatically corrects for changes in gas temperature.

Features:

Accuracy:

• AT series thermal mass flowmeter has well Repeatability, ± 0.1% of full scale. The accuracy of the system can reach ± 1 %. Although the accuracy of other kinds of flowmeter will be better than ± 1 %, the accuracy is hard to reach ± 1 % through the combination of temperature transmitter, pressure transmitter, secondary meter, the total error for the real system will be more than that value, especially when the component of flow changes. Because AT series thermal mass flowmeter directly measures mass flow, it has sensor and transmitter and display by its own. But the traditional gas flow meter needs to make up for a measurement system with temperature transmitter, pressure transmitter, secondary meter. According to reliable design theories, obviously, AT series thermal mass flowmeter possess a good reliabilities and measurement accuracies.


Wide Measuring Range:

• AT series thermal mass flowmeter use advanced intelligent chips and display alphanumeric 2 x 16 digit backlit LCD, it can display ten digits of cumulant flow and four digits of instantaneous flow and flow percentage and the self-check. There are three keys behind the display, which can switch display content and set various data. It also can use the remote-control which has three matching keys. You can do all operations by using the remote control with no cover opened. The unit of flow rate can set kg/h or Nm3/h. The connection has 4-20mA signal output and RS232 communicator, and adopting MODBUS or HART protocol.


Easy Installation:

• AT series thermal mass flowmeter can be installed on the level, uprightness and incline duct, but should be upright with a duct.

• AT series thermal mass flowmeter use flange hold way to install. It can provide a set of flange, bolt, and nut. series thermal mass flowmeter mate flange at random and used for welding on the trapping duct.

• AT series thermal mass flowmeter usually, need the 15D straight pipe. When the occasion cannot meet this requirement, you can choose our own rectifier.


Application:

• Industrial and Process Gas Mass Flow.

• Fuel Flow For Burners and Fuel Cells.

• NOX Control Using Ammonia

• Aeration Air and Digester Gas Waste Water Treatment Facilities

• Compressed Air

• Natural Gas

• Combustion Air

• Metering Semi-conductor Gases

• Chlorine Metering In Paper Industries

• Solvent and VOC Recovery

• Air Sampling

• General Purpose Mass Flow, Rd.

• Flow Calibration Standards


Technical Details:

• Applicable Duct Diameter Range: 6-10000 mm

• Mass Flow Measurement: Measure and display gas mass flow Resistant: Maximum internal duct pressure is 20 Mpa.

• Lower Flow Rate: Minimum upper limit flow rate is 0.5m/s, lower limit is 0 m/s

• Pipe Size: IN Line Type: 6-200mm, Insertion Type: 40-10000mm

• Power Supply: 24VDC+10%,>350mA (you can also use our private power supply DW2407), or 220VAC+10%

• Output: 4-20mA load resistance<350O (750O optional) communication output, RS-485, MODBUS,

• HART Power: Dissipation <8W suitable

• Medium: All kinds of gases (pure & stale gases), except for acetylene

• Display: Upper row cumulant flow displayed by ten digits,

• Bottom row instantaneous flow displayed by four digits (double rows displayed)

SELLER: Instronix Process Controls

ADDMAS Thermal Mass Flowmeters

Product code (MPN): ITB-F628117E
Availability:In Stock
₹ 65000.00  Incl. GST ₹ 55084.75 Excl. GST
  • Description
    ADDMAS Thermal Mass Flowmeters

    Minimum Order Quantity: 1
    1 Pack contains : 1 Unit

     

    At Thermal Mass Flowmeter is one of the most advanced flowmeters in gas mass monitoring. The sensor of AT Thermal Mass Flowmeter is related to flow rate of the gas mass and meet the situation which the temperature and pressure are unstable Thermal sensor consists of two sensing elements - a velocity sensor and a temperature sensor that automatically corrects for changes in gas temperature.

    Features:

    Accuracy:

    • AT series thermal mass flowmeter has well Repeatability, ± 0.1% of full scale. The accuracy of the system can reach ± 1 %. Although the accuracy of other kinds of flowmeter will be better than ± 1 %, the accuracy is hard to reach ± 1 % through the combination of temperature transmitter, pressure transmitter, secondary meter, the total error for the real system will be more than that value, especially when the component of flow changes. Because AT series thermal mass flowmeter directly measures mass flow, it has sensor and transmitter and display by its own. But the traditional gas flow meter needs to make up for a measurement system with temperature transmitter, pressure transmitter, secondary meter. According to reliable design theories, obviously, AT series thermal mass flowmeter possess a good reliabilities and measurement accuracies.


    Wide Measuring Range:

    • AT series thermal mass flowmeter use advanced intelligent chips and display alphanumeric 2 x 16 digit backlit LCD, it can display ten digits of cumulant flow and four digits of instantaneous flow and flow percentage and the self-check. There are three keys behind the display, which can switch display content and set various data. It also can use the remote-control which has three matching keys. You can do all operations by using the remote control with no cover opened. The unit of flow rate can set kg/h or Nm3/h. The connection has 4-20mA signal output and RS232 communicator, and adopting MODBUS or HART protocol.


    Easy Installation:

    • AT series thermal mass flowmeter can be installed on the level, uprightness and incline duct, but should be upright with a duct.

    • AT series thermal mass flowmeter use flange hold way to install. It can provide a set of flange, bolt, and nut. series thermal mass flowmeter mate flange at random and used for welding on the trapping duct.

    • AT series thermal mass flowmeter usually, need the 15D straight pipe. When the occasion cannot meet this requirement, you can choose our own rectifier.


    Application:

    • Industrial and Process Gas Mass Flow.

    • Fuel Flow For Burners and Fuel Cells.

    • NOX Control Using Ammonia

    • Aeration Air and Digester Gas Waste Water Treatment Facilities

    • Compressed Air

    • Natural Gas

    • Combustion Air

    • Metering Semi-conductor Gases

    • Chlorine Metering In Paper Industries

    • Solvent and VOC Recovery

    • Air Sampling

    • General Purpose Mass Flow, Rd.

    • Flow Calibration Standards


    Technical Details:

    • Applicable Duct Diameter Range: 6-10000 mm

    • Mass Flow Measurement: Measure and display gas mass flow Resistant: Maximum internal duct pressure is 20 Mpa.

    • Lower Flow Rate: Minimum upper limit flow rate is 0.5m/s, lower limit is 0 m/s

    • Pipe Size: IN Line Type: 6-200mm, Insertion Type: 40-10000mm

    • Power Supply: 24VDC+10%,>350mA (you can also use our private power supply DW2407), or 220VAC+10%

    • Output: 4-20mA load resistance<350O (750O optional) communication output, RS-485, MODBUS,

    • HART Power: Dissipation <8W suitable

    • Medium: All kinds of gases (pure & stale gases), except for acetylene

    • Display: Upper row cumulant flow displayed by ten digits,

    • Bottom row instantaneous flow displayed by four digits (double rows displayed)

  • FAQs
    Need some help? Ask us!