Specification:
Type | 3 Phase Input -3 phase Output | 1 Phase Input - 1 Phase Output |
Technology | Dsc Based Double Conversion Online Ups System With True Galvanic Isolation | |
Capacity | 10 kva 15kva 20 kva 25 kva 30 kva 40 kva 50 kva | 5 kva 7.5 kva 10 kva |
INPUT | ||
NO.OF PHASE | 3Phase - 5 Wire With Neutral and Earth | 1 Phase - 3 Wire With Neutral And Earth |
Voltage Range | 310v -480 Volts AC | 160V -280 Volts AC |
input Frequency Range | 45 to 55 HZ. | 45 to 55 Hz. |
OUTPUT | ||
Power | 8000W 12000W 16000W 20000W 24000W 32000W 40000W | 4000W 6000W 8000W |
Load PF Range | 0.8 Lagging | 0.8 Lagging |
Phase | 3 Phase - 5 Wire With Neutral Abd Earth | 1 Phase - 3 Wire With Neutral Abd Earth |
Output WaveFrom | Pure Sine Wave | Pure Sine Wave |
Voltage | 415 + 1% | 220 + 1% |
Frequency | 50Hz + -0.1% | 50Hz + -0.1% |
Load Crest Factor | 3;1 | 3;1 |
Output Voltage THD | <=3% On Linear | <=3% On Linear |
Loading Capacity | 110% For 2 Minutes | 110% For 2 Minutes |
Transient recovery | + 4 % Under Full Load Change And Corrected And Within 1 Cycles | |
BATTERIES /CHARGER | SIX PULSE CHARGER | SMPS CHARGER |
No.Of 12V Batteries | 30 | 15 |
Voltage | 360 V DC | 180 V DC |
Charging Current | 1 Amp To 10 Amp | 1 Amp To 10 Amp |
GENERAL | ||
Indication | LCD Panel & LED | LCD Panel & LED |
Alarm | Mains Failure, Battery Low, Over Load, Short Circuit | |
Protection | Short Circuit, Thermal, Battery Low/ High, Mains High/Low, Output High/Low, Overload | |
Cooling | Forced Air Cooling | Forced Air Cooling |
Ups Efficiency | >85% | >85% |
Operating Temperature | 0-40 C | 0-40 C |
Operating Humidity | 95% Condensing | 95% Condensing |
Accoustic Noise | <55 Db At 1 Meter | <55 Db At 1 Meter |
Specification:
Type | 3 Phase Input -3 phase Output | 1 Phase Input - 1 Phase Output |
Technology | Dsc Based Double Conversion Online Ups System With True Galvanic Isolation | |
Capacity | 10 kva 15kva 20 kva 25 kva 30 kva 40 kva 50 kva | 5 kva 7.5 kva 10 kva |
INPUT | ||
NO.OF PHASE | 3Phase - 5 Wire With Neutral and Earth | 1 Phase - 3 Wire With Neutral And Earth |
Voltage Range | 310v -480 Volts AC | 160V -280 Volts AC |
input Frequency Range | 45 to 55 HZ. | 45 to 55 Hz. |
OUTPUT | ||
Power | 8000W 12000W 16000W 20000W 24000W 32000W 40000W | 4000W 6000W 8000W |
Load PF Range | 0.8 Lagging | 0.8 Lagging |
Phase | 3 Phase - 5 Wire With Neutral Abd Earth | 1 Phase - 3 Wire With Neutral Abd Earth |
Output WaveFrom | Pure Sine Wave | Pure Sine Wave |
Voltage | 415 + 1% | 220 + 1% |
Frequency | 50Hz + -0.1% | 50Hz + -0.1% |
Load Crest Factor | 3;1 | 3;1 |
Output Voltage THD | <=3% On Linear | <=3% On Linear |
Loading Capacity | 110% For 2 Minutes | 110% For 2 Minutes |
Transient recovery | + 4 % Under Full Load Change And Corrected And Within 1 Cycles | |
BATTERIES /CHARGER | SIX PULSE CHARGER | SMPS CHARGER |
No.Of 12V Batteries | 30 | 15 |
Voltage | 360 V DC | 180 V DC |
Charging Current | 1 Amp To 10 Amp | 1 Amp To 10 Amp |
GENERAL | ||
Indication | LCD Panel & LED | LCD Panel & LED |
Alarm | Mains Failure, Battery Low, Over Load, Short Circuit | |
Protection | Short Circuit, Thermal, Battery Low/ High, Mains High/Low, Output High/Low, Overload | |
Cooling | Forced Air Cooling | Forced Air Cooling |
Ups Efficiency | >85% | >85% |
Operating Temperature | 0-40 C | 0-40 C |
Operating Humidity | 95% Condensing | 95% Condensing |
Accoustic Noise | <55 Db At 1 Meter | <55 Db At 1 Meter |