Categories

Technocom Marketing

Multilin B30 Multiple Sections Low Impedance Busbar Protection

₹ 35000.00  Incl. GST ₹ 29661.02 Excl. GST

Description

The Multilin B30 bus protection relay features integrated protection, visualization and metering for LV, MV, HV and EHV busbars, providing cost-effective, feature-focused centralized or distributed busbar protection scheme.


Current1A - 5A
TypeProtection Relay
Usage/ApplicationMultiple Sections Low Impedance Busbar Protection


Voltage TypeAC/DC
The Multilin B30 bus protection relay features integrated protection, visualization and metering for LV, MV, HV and EHV busbars, providing cost-effective, feature-focused centralized or distributed busbar protection scheme. Use the B30 to protect busbars with up to 16 feeders with up to six three-phase differential zones. The Multilin B30 relay is a cost-effective alternative to high-impedance schemes, ideal for breaker-and-half bus schemes, with integrated feeder backup protection.
Key Benefits
  • High speed differential protection algorithm for sub-cycle trip times of 0.75 power cycle
  • Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and highly flexible process bus support (IEC 61850-9-2LE or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization and reduced cost of ownership
  • Fits buses with conventional CTs or optical CTs communicating on IEC 61850-9-2LE or IEC 61869 standard comm protocols
  • Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
  • Superior CT saturation detection with only 2 msec of saturation-free current for enhanced through-fault stability
  • Advanced automation capabilities for providing customized protection and control solutions
  • Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific customization
  • Robust network security enabling Critical Infrastructure Protection through user command logging, and dual permission access control
  • Simplified system integration supporting serial and Ethernet interfaces and multiple protocols
  • An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors

Applications
  • Re-configurable simple bus applications, up to 16 feeders and 6 differential zones with breaker failure
  • Centralized (six feeders, two zones) or distributed (sixteen feeders, six zones) busbar schemes
  • Integrated bus differential, backup protection visualization and metering for LV, MV, HV and EHV substations.

 



Minimum Order Quantity: 1
1 Pack contains : 1 Unit
SELLER: Technocom Marketing

Multilin B30 Multiple Sections Low Impedance Busbar Protection

Product code (MPN): ITB-69C10C67
Availability:In Stock
₹ 35000.00  Incl. GST ₹ 29661.02 Excl. GST
  • Description
    The Multilin B30 bus protection relay features integrated protection, visualization and metering for LV, MV, HV and EHV busbars, providing cost-effective, feature-focused centralized or distributed busbar protection scheme.


    Current1A - 5A
    TypeProtection Relay
    Usage/ApplicationMultiple Sections Low Impedance Busbar Protection


    Voltage TypeAC/DC
    The Multilin B30 bus protection relay features integrated protection, visualization and metering for LV, MV, HV and EHV busbars, providing cost-effective, feature-focused centralized or distributed busbar protection scheme. Use the B30 to protect busbars with up to 16 feeders with up to six three-phase differential zones. The Multilin B30 relay is a cost-effective alternative to high-impedance schemes, ideal for breaker-and-half bus schemes, with integrated feeder backup protection.
    Key Benefits
    • High speed differential protection algorithm for sub-cycle trip times of 0.75 power cycle
    • Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and highly flexible process bus support (IEC 61850-9-2LE or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization and reduced cost of ownership
    • Fits buses with conventional CTs or optical CTs communicating on IEC 61850-9-2LE or IEC 61869 standard comm protocols
    • Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications
    • Superior CT saturation detection with only 2 msec of saturation-free current for enhanced through-fault stability
    • Advanced automation capabilities for providing customized protection and control solutions
    • Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific customization
    • Robust network security enabling Critical Infrastructure Protection through user command logging, and dual permission access control
    • Simplified system integration supporting serial and Ethernet interfaces and multiple protocols
    • An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors

    Applications
    • Re-configurable simple bus applications, up to 16 feeders and 6 differential zones with breaker failure
    • Centralized (six feeders, two zones) or distributed (sixteen feeders, six zones) busbar schemes
    • Integrated bus differential, backup protection visualization and metering for LV, MV, HV and EHV substations.

     



    Minimum Order Quantity: 1
    1 Pack contains : 1 Unit
  • FAQs
    Need some help? Ask us!