The Megger TTR25-1 is an automatic hand-held battery-operated transformer turns ratio test set. It is used to measure the turns ratio, excitation current, and polarity of windings in single- and three-phase distribution and power transformers (tested phase by phase), potential & current transformers, and tapped transformers
Battery LifeUp to 12 hours of field operation
Current (rms) Accuracy5% rdg +-0.5 mA
Dimensions240 H x 115 W x 50 D mm (9.5 H x 4.5 W x 1.9 D in.)
Display Full GraphicsLCD module, adjustable back-lighting, wide temperature range, 128 x 64 dots (21 characters by 8 lin
Excitation Current Range0 to 100 mA, 4-digit resolution
Excitation Voltage8 V rms for testing distribution or power transformers and PTs; 0.5, 1.5, or 8 V ac rms for testing
Measurement MethodANSI/IEEE C57.12.90 and IEC 600076.1 (2000)
Measuring TimeLess than 5 seconds
Operating temperature-20 Degree Celsius to 55 Degree Celsius (-5 Deg F to 130 Deg F)
Protective DevicesHigh voltage side shorting relay, transient voltage suppressors and gas surge voltage protectors
Safety/EMC/VibrationMeets the requirements of IEC-61010, CE and ASTM D999.75
Storage Temperature-50 Degree Celsius to 60 Degree Celsius (-55 Deg F to 140 Deg F)
Test Frequency55 Hz internally generated providing a universal 50/60 Hz test set
Transformer PolarityNormal or reversed
Turns Ratio Accuracy0.20% (0.8 to 4,000)
Turns Ratio Range0.8 to 20,000, 5 digit resolution
Type of PowerSix standard "AA" (IEC LR-6) alkaline batteries
WeightApproximately 1.3 kg (2.8 lb), including leads
 
SELLER: Lucents Technologies India Private Limited

TTR25-1 Hand-held Transformer Turns Ratio Tester

Product code (MPN): ITB-5F779AE7
Availability:In Stock
₹ 325000.00  Incl. GST ₹ 275423.73 Excl. GST
  • Description
    The Megger TTR25-1 is an automatic hand-held battery-operated transformer turns ratio test set. It is used to measure the turns ratio, excitation current, and polarity of windings in single- and three-phase distribution and power transformers (tested phase by phase), potential & current transformers, and tapped transformers
    Battery LifeUp to 12 hours of field operation
    Current (rms) Accuracy5% rdg +-0.5 mA
    Dimensions240 H x 115 W x 50 D mm (9.5 H x 4.5 W x 1.9 D in.)
    Display Full GraphicsLCD module, adjustable back-lighting, wide temperature range, 128 x 64 dots (21 characters by 8 lin
    Excitation Current Range0 to 100 mA, 4-digit resolution
    Excitation Voltage8 V rms for testing distribution or power transformers and PTs; 0.5, 1.5, or 8 V ac rms for testing
    Measurement MethodANSI/IEEE C57.12.90 and IEC 600076.1 (2000)
    Measuring TimeLess than 5 seconds
    Operating temperature-20 Degree Celsius to 55 Degree Celsius (-5 Deg F to 130 Deg F)
    Protective DevicesHigh voltage side shorting relay, transient voltage suppressors and gas surge voltage protectors
    Safety/EMC/VibrationMeets the requirements of IEC-61010, CE and ASTM D999.75
    Storage Temperature-50 Degree Celsius to 60 Degree Celsius (-55 Deg F to 140 Deg F)
    Test Frequency55 Hz internally generated providing a universal 50/60 Hz test set
    Transformer PolarityNormal or reversed
    Turns Ratio Accuracy0.20% (0.8 to 4,000)
    Turns Ratio Range0.8 to 20,000, 5 digit resolution
    Type of PowerSix standard "AA" (IEC LR-6) alkaline batteries
    WeightApproximately 1.3 kg (2.8 lb), including leads
     