Categories

Ambetronics Engineers Private Limited

Ambetronics Clean Room Differential Pressure Monitor

₹ 9750.00  Incl. GST ₹ 8262.71 Excl. GST

Description

Description:-The Clean Room Differential Pressure Monitor CRM-111-1 is the latest upgraded, flush mounted monitoring equipment designed for continuous monitoring of Differential Pressure at research labs, cold storage warehouses in industries like Pharma manufacturing & packaging, Animal Housing, Hospital industries and can be integrated with HVAC systems. Features:- • 7 Segments L.E.D. display Indication for Differential Pressure.• User Programmable 2 no. Alarms AL1 , AL2.• Intergrated Buzzer for Alarm limits violation with Acknowledgment facility.• Software calibration facility, ‘Calibration Due' and ‘Sensor Replace' indication .• Password protected programming• Isolated RS-485 with Modbus RTU Protocol communication for PLC, SCADA etc.• Optional in built 2 No Relay.• Optional 4-20mA output. Technical Specifications:- •Display : 4 digit Seven Segment 0.4" Red LED display for Differential Pressure Indication •Status indication : 2 LEDs for Alarms; Integrated Buzzer for process violation of Alarm limits. •Sensors : Integrated Differential Pressure Sensor; •Range: (-100 to 100) mmWC, Resolution: 0.1 •Range: (-10 to 10) cmWC, Resolution: 0.1 •Range: (-7.5 to 7.5) mmHG, Resolution: 0.1 •Range: (-1000 to 1000) Pascal, Resolution: 1 •Range: (-10 to 10) Hectopascal, Resolution: 0.1 •NOTE : Other Differential Pressure Range/Unit, Available on request, contact to factory. •Accuracy:- Differential Pressure : ± 1 % of FS •Communication : Isolated RS-485 communication with Modbus RTU Protocol •No. of salve ID : 1-250 •Programmable parameter : 9600 bps, Parity, Data bits, Stop bits •Set point: 2Nos. AL1, AL2 User Programmable •Programming of parameters : 3 Nos. push button front keys (with password protection) •Alarm logic : High or Low, user programmable •Operating Ambient Temp. : 0 to 50°C •Humidity : Below 90% RH, Non condensing. •Supply voltage : 24VDC ± 10% •Power consumption : Less than 1.2 watt at 24VDC •Flush mounting plate : SS-304 •Front plate size : 110 mm(W) x90 mm(H) •Back enclosure : 76 mm (W) x70mm(H) x45mm(D); MS with powder coated •Mounting : Modular wall mounting with Stainless Steel Front Applications:- • Clean room application in Pharmaceutical• Pharma Environments monitoring applications.• HVAC (Heating, ventilation, Air conditioning, Cooling).• Animal house clean room

Minimum Order Quantity: 1
1 Pack contains : 1 Unit
SELLER: Ambetronics Engineers Private Limited

Ambetronics Clean Room Differential Pressure Monitor

Product code (MPN): ITB-46C63ACE
Availability:In Stock
₹ 9750.00  Incl. GST ₹ 8262.71 Excl. GST
  • Description
    Description:-The Clean Room Differential Pressure Monitor CRM-111-1 is the latest upgraded, flush mounted monitoring equipment designed for continuous monitoring of Differential Pressure at research labs, cold storage warehouses in industries like Pharma manufacturing & packaging, Animal Housing, Hospital industries and can be integrated with HVAC systems. Features:- • 7 Segments L.E.D. display Indication for Differential Pressure.• User Programmable 2 no. Alarms AL1 , AL2.• Intergrated Buzzer for Alarm limits violation with Acknowledgment facility.• Software calibration facility, ‘Calibration Due' and ‘Sensor Replace' indication .• Password protected programming• Isolated RS-485 with Modbus RTU Protocol communication for PLC, SCADA etc.• Optional in built 2 No Relay.• Optional 4-20mA output. Technical Specifications:- •Display : 4 digit Seven Segment 0.4" Red LED display for Differential Pressure Indication •Status indication : 2 LEDs for Alarms; Integrated Buzzer for process violation of Alarm limits. •Sensors : Integrated Differential Pressure Sensor; •Range: (-100 to 100) mmWC, Resolution: 0.1 •Range: (-10 to 10) cmWC, Resolution: 0.1 •Range: (-7.5 to 7.5) mmHG, Resolution: 0.1 •Range: (-1000 to 1000) Pascal, Resolution: 1 •Range: (-10 to 10) Hectopascal, Resolution: 0.1 •NOTE : Other Differential Pressure Range/Unit, Available on request, contact to factory. •Accuracy:- Differential Pressure : ± 1 % of FS •Communication : Isolated RS-485 communication with Modbus RTU Protocol •No. of salve ID : 1-250 •Programmable parameter : 9600 bps, Parity, Data bits, Stop bits •Set point: 2Nos. AL1, AL2 User Programmable •Programming of parameters : 3 Nos. push button front keys (with password protection) •Alarm logic : High or Low, user programmable •Operating Ambient Temp. : 0 to 50°C •Humidity : Below 90% RH, Non condensing. •Supply voltage : 24VDC ± 10% •Power consumption : Less than 1.2 watt at 24VDC •Flush mounting plate : SS-304 •Front plate size : 110 mm(W) x90 mm(H) •Back enclosure : 76 mm (W) x70mm(H) x45mm(D); MS with powder coated •Mounting : Modular wall mounting with Stainless Steel Front Applications:- • Clean room application in Pharmaceutical• Pharma Environments monitoring applications.• HVAC (Heating, ventilation, Air conditioning, Cooling).• Animal house clean room

    Minimum Order Quantity: 1
    1 Pack contains : 1 Unit
  • FAQs
    Need some help? Ask us!