We are the leading manufacturer of Signal Isolator in Delhi
Design Based on F/V and V/F linear circuit.
Input types RTD (Pt-100) / 2 or 3 wire or Thermocouple (J/K/ Types – type to be specified) or mV, mA input or Load cell, pressure sensor, pH/ORP sensor etc. generating DC current or voltage. AC input - Current (through external CT) (0-1)A or (0-5)A or Voltage (0-110)VAC or (0-230)VAC or 415VAC Frequency input DC levels of clock pulses of max. 10KHZ. @ (12-24)VDC
Range User may specify the required temperature range (for RTD or T/C input). For other inputs the required calibration range can be specified.
Output (4-20) mA, (0-20) mA, (0-1) VDC, (0-5) VDC, (0-10) VDC, Frequency (0-1)KHz, (0-5)KHz, (0-10)KHz etc. proportional to the specified input range. For current output, RL (max.) = 500 Ohms. For voltage output, RL (min) = 10K Ohms.
No. of Outputs Maximum 4 parallel independent outputs can be provided for single input.
Accuracy For Thermocouple and RTD Input, the calibration of output is done for the best straight line fit to give accuracy of /- 0.5% of the range. For other input the linearity depends on the input signal, where output accuracy is absolute to the input.
Calibration On site calibration facility through ZERO and SPAN presets accessible to the user.
Isolation Input and Output are optically isolated for DC and frequency inputs and galvanically isolated for the AC inputs.
Isolation Voltage Greater than 2.5KV.
Mounting DIN rail mounting ABS enclosure.
Supply 90 -260 VAC, 50/60Hz or 24VDC @ 200mA
Size 65(W) x 80(H) x 125(D) mm.


Minimum Order Quantity: 1
1 Pack contains : 1 Unit
SELLER: PYROTRON (INDIA) INC

Signal Isolator

Product code (MPN): ITB-93CED5F1
Availability:In Stock
₹ 10500.00  Incl. GST ₹ 8898.31 Excl. GST
  • Description
    We are the leading manufacturer of Signal Isolator in Delhi
    Design Based on F/V and V/F linear circuit.
    Input types RTD (Pt-100) / 2 or 3 wire or Thermocouple (J/K/ Types – type to be specified) or mV, mA input or Load cell, pressure sensor, pH/ORP sensor etc. generating DC current or voltage. AC input - Current (through external CT) (0-1)A or (0-5)A or Voltage (0-110)VAC or (0-230)VAC or 415VAC Frequency input DC levels of clock pulses of max. 10KHZ. @ (12-24)VDC
    Range User may specify the required temperature range (for RTD or T/C input). For other inputs the required calibration range can be specified.
    Output (4-20) mA, (0-20) mA, (0-1) VDC, (0-5) VDC, (0-10) VDC, Frequency (0-1)KHz, (0-5)KHz, (0-10)KHz etc. proportional to the specified input range. For current output, RL (max.) = 500 Ohms. For voltage output, RL (min) = 10K Ohms.
    No. of Outputs Maximum 4 parallel independent outputs can be provided for single input.
    Accuracy For Thermocouple and RTD Input, the calibration of output is done for the best straight line fit to give accuracy of /- 0.5% of the range. For other input the linearity depends on the input signal, where output accuracy is absolute to the input.
    Calibration On site calibration facility through ZERO and SPAN presets accessible to the user.
    Isolation Input and Output are optically isolated for DC and frequency inputs and galvanically isolated for the AC inputs.
    Isolation Voltage Greater than 2.5KV.
    Mounting DIN rail mounting ABS enclosure.
    Supply 90 -260 VAC, 50/60Hz or 24VDC @ 200mA
    Size 65(W) x 80(H) x 125(D) mm.