Water level indicator
GENERAL DESCRIPTION: Teknika TE11110 Pump Indicator cum Controller / Water Level Controller Relay finds application in automatic on and off of pumps and display of various water levels. The Relay senses the liquid levels in tanks at ground level or overhead / on building top etc. Five to eight level sensing ensures Various are available.
• Led indications are provided to indicate at various levels L1 to L5.
• The digital indicator indicates the % in the tank when water is at the level of probe.
• Eg 0, 20%, 40% 60% 80% 100% when probes are set equally at these levels in the tank. This is the default setting.
• These levels are programmable and the probes can be set at whatever levels desired by user and that % programmed as desired.
• A potential free contact is energized when the level is below L1 and above L5. This is the default value.
• The below level and above level relay energisation is also programmable. Lo level, Hi level are programmable between L1 and L5. However L5 has to be above L1.Silent Feature:
• Used in Water Pumping applications
• Many options available-
• Low voltage probes to ensure safety and avoid polarization of electrodes in liquid.
• Wide temperature withstand range
• Can be wired through a pressure switch
• Suitable for mounting inside panel.


Minimum Order Quantity: 1
1 Pack contains : 1 Unit

SPECIFICATIONS 
• Voltage rating: 230 Vac at 1,2  . 
• Pump Contact: Below L1 and above L5 programmable. 
• Water sensing: Through Stainless steel  molded conductive probes at LEH (Sump or Tank).  
• Long Life sensors: Regular cleaning not required 
• Burden: 5VA at setting 
• Temperature range: -20+55’C 
• Repeat time accuracy: +/- 2% of setting 
• Contact rating: 5A max potential free 
• Thermal rating: Relay will withstand continuously  rated voltage. Surge capacity is twice rated voltage 
 

SELLER: Teknika Electronics

Water level indicator

Product code (MPN): ITB-0891E7C0
Availability:In Stock
₹ 3000.00  Incl. GST ₹ 2542.37 Excl. GST
  • Description
    Water level indicator
    GENERAL DESCRIPTION: Teknika TE11110 Pump Indicator cum Controller / Water Level Controller Relay finds application in automatic on and off of pumps and display of various water levels. The Relay senses the liquid levels in tanks at ground level or overhead / on building top etc. Five to eight level sensing ensures Various are available.
    • Led indications are provided to indicate at various levels L1 to L5.
    • The digital indicator indicates the % in the tank when water is at the level of probe.
    • Eg 0, 20%, 40% 60% 80% 100% when probes are set equally at these levels in the tank. This is the default setting.
    • These levels are programmable and the probes can be set at whatever levels desired by user and that % programmed as desired.
    • A potential free contact is energized when the level is below L1 and above L5. This is the default value.
    • The below level and above level relay energisation is also programmable. Lo level, Hi level are programmable between L1 and L5. However L5 has to be above L1.Silent Feature:
    • Used in Water Pumping applications
    • Many options available-
    • Low voltage probes to ensure safety and avoid polarization of electrodes in liquid.
    • Wide temperature withstand range
    • Can be wired through a pressure switch
    • Suitable for mounting inside panel.


    Minimum Order Quantity: 1
    1 Pack contains : 1 Unit

    SPECIFICATIONS 
    • Voltage rating: 230 Vac at 1,2  . 
    • Pump Contact: Below L1 and above L5 programmable. 
    • Water sensing: Through Stainless steel  molded conductive probes at LEH (Sump or Tank).  
    • Long Life sensors: Regular cleaning not required 
    • Burden: 5VA at setting 
    • Temperature range: -20+55’C 
    • Repeat time accuracy: +/- 2% of setting 
    • Contact rating: 5A max potential free 
    • Thermal rating: Relay will withstand continuously  rated voltage. Surge capacity is twice rated voltage 
     

  • FAQs