Standard test ranges The RCDT300 series can perform 1/2I, 1xI and 5xI tests on RCDs rated at 30 mA, 100 mA, 300 mA and 500 mA ongeneral and selective (time delayed) RCDs. The RCDT320/ 330 can also test RCDs rated at 10 mA and 1000 mA. All units offer DC testing of RCD’s.Test times for normal and Selective RCDs are:
Normal Selective1/2I 2s 2sI 300ms 2s5I 40ms 150msn 5I tests are available on RCDs rated up to 100 mA.Polarity All RCDs can be tested at 0º or 180ºSelective RCDs Selective breakers have a time delay in tripping. When selected, trip test times are extended and a 30s delay is allowed between the measurement of the fault voltage and the application of the test current.Touch voltage Touch voltage is measured at the start of the RCD test. If enabled it is displayed on the analogue arc on completion of testing.Touch voltage inhibit is selectable from 25 V or 50 V.FEATURES
- Tests standard, DC, selective, and programmable RCDs
- Ramp testing
- Auto (Remote) testing
- 3 Phase safen Enables testing on 110 V centre tapped supplies.
- Tough rubber armoured case with built-in covern Weatherproof to IP54
- USB interface for downloading test result