Mechmatics Engineering Private Limited

Vortex Orifice Reynolds Fluid Mechanics

₹ 65000.00  Incl. GST ₹ 55084.75 Excl. GST

Description

The equipment uses a dye injection technique to enable observation of flow conditions
Drive180 W PMDC Motor
Measurement ProbeVertical and horizontal traveling pointer gauge
Orifice Diameters8, 10 and 12 mm
Tank Diameter250 mm
Tank Height280 mm
MaterialStainless Steel


ColorWhite
Usage/ApplicationIndustrial and Academic Training
FinishingHigh Quality
Automation GradeAutomatic

Features :
  • SHS- 40 Frame with Metal Coat Paint
  • Reservior Tanks Made of SS-304
  • All Wooden Boards are Laminated
  • Storage Cub-board provided
  • Pumps are CROMPTON Make.
  • Plumbing is of FINOLEX make.
  • Electrical Accessories of ANCHOR
  • All Machining parts Crome Coated.


Free Forced VortexThis equipment is designed to produce and measure the characteristics of free and forced vortices. The apparatus comprises a clear acrylic cylinder on a plinth designed to produce and measure free and forced vortices. The free vortex is generated by water discharging through an interchangeable orifice in the base of the cylinder and the resulting profile is measured using a combined X-Y scale. The forced vortex is induced by a paddle in the base of the cylinder. The profile of the forced vortex is determined using a series of X-Y Probe.



Orifice and MouthpieceThis equipment permits calibration of orifices of differing diameters. In the orifice and free jet flow accessory a constant head tank will be fed with water from the common Sump. The orifice is installed at the base of the tank. The head will be maintained at constant value by an adjustable overflow pipe and will be indicated by a level scale. A jet trajectory tracing device allows the path followed by the jet to be ascertained.

Specifications
  • Orifice Diameters : 10;12 and 14 mm
  • X-Y Probe
  • Mouthpiece 12 mm Nos.1

Reynold Apparatus
This accessory should be intended to reproduce the classic experiments conducted by Professor Osborne Reynolds concerning the nature of laminar and turbulent flow. The equipment operates in a vertical (or Horizontal) mode. A header tank containing stilling media provides a constant head of water through a bell mouth entry to the flow visualization pipe. Flow through this pipe is be regulated using a control valve provided at the discharge end. The flow rate of water through the pipe should be measured using the measuring cylinder. Velocity of the water can therefore be determined to allow calculation of Reynolds’ number.

The equipment uses a dye injection technique to enable observation of flow conditions

Specifications
  • Test Pipe : Acrylic, 25 mm dia., 500 mm long
  • Dye Reservoir : 500 ml
SELLER: Mechmatics Engineering Private Limited

Vortex Orifice Reynolds Fluid Mechanics

Product code (MPN): ITB-1BB2A926
Availability:In Stock
₹ 65000.00  Incl. GST ₹ 55084.75 Excl. GST
  • Description
    The equipment uses a dye injection technique to enable observation of flow conditions
    Drive180 W PMDC Motor
    Measurement ProbeVertical and horizontal traveling pointer gauge
    Orifice Diameters8, 10 and 12 mm
    Tank Diameter250 mm
    Tank Height280 mm
    MaterialStainless Steel


    ColorWhite
    Usage/ApplicationIndustrial and Academic Training
    FinishingHigh Quality
    Automation GradeAutomatic

    Features :
    • SHS- 40 Frame with Metal Coat Paint
    • Reservior Tanks Made of SS-304
    • All Wooden Boards are Laminated
    • Storage Cub-board provided
    • Pumps are CROMPTON Make.
    • Plumbing is of FINOLEX make.
    • Electrical Accessories of ANCHOR
    • All Machining parts Crome Coated.


    Free Forced VortexThis equipment is designed to produce and measure the characteristics of free and forced vortices. The apparatus comprises a clear acrylic cylinder on a plinth designed to produce and measure free and forced vortices. The free vortex is generated by water discharging through an interchangeable orifice in the base of the cylinder and the resulting profile is measured using a combined X-Y scale. The forced vortex is induced by a paddle in the base of the cylinder. The profile of the forced vortex is determined using a series of X-Y Probe.



    Orifice and MouthpieceThis equipment permits calibration of orifices of differing diameters. In the orifice and free jet flow accessory a constant head tank will be fed with water from the common Sump. The orifice is installed at the base of the tank. The head will be maintained at constant value by an adjustable overflow pipe and will be indicated by a level scale. A jet trajectory tracing device allows the path followed by the jet to be ascertained.

    Specifications
    • Orifice Diameters : 10;12 and 14 mm
    • X-Y Probe
    • Mouthpiece 12 mm Nos.1

    Reynold Apparatus
    This accessory should be intended to reproduce the classic experiments conducted by Professor Osborne Reynolds concerning the nature of laminar and turbulent flow. The equipment operates in a vertical (or Horizontal) mode. A header tank containing stilling media provides a constant head of water through a bell mouth entry to the flow visualization pipe. Flow through this pipe is be regulated using a control valve provided at the discharge end. The flow rate of water through the pipe should be measured using the measuring cylinder. Velocity of the water can therefore be determined to allow calculation of Reynolds’ number.

    The equipment uses a dye injection technique to enable observation of flow conditions

    Specifications
    • Test Pipe : Acrylic, 25 mm dia., 500 mm long
    • Dye Reservoir : 500 ml
  • FAQs
    Need some help? Ask us!