Digital Load Cell Each Digital Load Cell has an individual A/D converter. This helps in generating higher internal counts for the total system and hence a lower division size can be achieved leading to higher accuracy.The output from digital load cell is in digital form and hence the distance from weigh platform to weigh room can be up to 300m without any distortion in weight display.Digital Load Cells are equipped with better lighting & electrical protections. Even the problem of flickering does not exist in Digital Load Cell. Thus results in better performance of the load cells.Installation of Digital Load Cell save lots of time and effort, that results in saving of labor and maintenance cost. Application
Truck Weighbridge
Tank and hopper weighing
Tensile testing
Get best price for Weighbridge load cell
Material
Alloy Steel
Ingress Protection
IP68
Application
Tensile Testing Machine
Combined Error
+/- 0.02% F.S
Creep Error (30 minutes)
+/- 0.02 % FS
Temperature Effect on Zero
+/- 0.020 % FS/DegC
Temperature Effect on Output
+/- 0.015 % FS/DegC
Zero balance
+/- 1% FS
Maximum Safe Overload
150% FS
Ultimate Safe Overload
300% FS
Recommended Excitation Voltage
5 to 15V DC
Insulation resistance at 50V DC
>= 1000 M Ohm
Compensated Temperature Range
-10 to +40 Deg C
Operating Temperatue Range
-30 to +70 Deg C
Cable Length
10-20 m
Minimum Order Quantity: 1 1 Pack contains : 1 Unit
Digital Load Cell Each Digital Load Cell has an individual A/D converter. This helps in generating higher internal counts for the total system and hence a lower division size can be achieved leading to higher accuracy.The output from digital load cell is in digital form and hence the distance from weigh platform to weigh room can be up to 300m without any distortion in weight display.Digital Load Cells are equipped with better lighting & electrical protections. Even the problem of flickering does not exist in Digital Load Cell. Thus results in better performance of the load cells.Installation of Digital Load Cell save lots of time and effort, that results in saving of labor and maintenance cost. Application
Truck Weighbridge
Tank and hopper weighing
Tensile testing
Get best price for Weighbridge load cell
Material
Alloy Steel
Ingress Protection
IP68
Application
Tensile Testing Machine
Combined Error
+/- 0.02% F.S
Creep Error (30 minutes)
+/- 0.02 % FS
Temperature Effect on Zero
+/- 0.020 % FS/DegC
Temperature Effect on Output
+/- 0.015 % FS/DegC
Zero balance
+/- 1% FS
Maximum Safe Overload
150% FS
Ultimate Safe Overload
300% FS
Recommended Excitation Voltage
5 to 15V DC
Insulation resistance at 50V DC
>= 1000 M Ohm
Compensated Temperature Range
-10 to +40 Deg C
Operating Temperatue Range
-30 to +70 Deg C
Cable Length
10-20 m
Minimum Order Quantity: 1 1 Pack contains : 1 Unit