Ventilator LP6

₹ 65000.00  Incl. GST ₹ 55084.75 Excl. GST

Description

Our durable LP Series of portble volume ventilator have a repurarion for dependability. They are built with a patented brushes motor.

Front Panel Controls :

Mode: Standby, Assist/Control, SIMV or Pressure Cycle
Low Pressure Alarm: Set limit for Low Pressure alarm 2 to 32
cmH2O in increments of 2 cmH2O
High Pressure Alarm Limit: (Assist/Control, SIMV Modes) or limit
For Pressure Cycle mode: 15 to 90 cmH2O in increments of 5 cmH2O
Volume: Push-to-turn knob: 100 to 2200 mL
Breath Rate: 1 to 20 BPM in increments of 1 BPM and 22 to 38

Inspiratory Time: 0.5 to1.0 sec in increments of 0.1 sec;
1.2 sec; and 1.5 to 5.5 sec in increments of 0.5 sec
Breathing Effort: Push-to-turn knob sets pressure level to detect
breathing effort (-10 cmH2O/hPa to +10 cmH2O)


Front Panel Input : 

• Patient Pressure: Port for connection to proximal pressure line of patient circuit

Front Panel Output :

• Patient Air: 22 mm x 15 mm tube for connection to bacteria filter
• Exhalation Valve: Port for connection to exhalation valve of patient circuit.

Indicators, Normal Events :

• Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can also display battery charge and machine hrs of operation
• Breathing Effort: Green LED activated by adequate patient breathing effort
• Power: LEDs indicate operating power source: green AC Pwr/Batt Chg, amber External Battery, flashing amber Internal Battery
• Alarms: Flashing red LEDs: Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover.

Audible Alarms :

• Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, Setting Error, Power Switchover
• Steady Tone: Loss of microprocessor control
• Reminder Tone: Every 5 mins when powered by Internal Battery,each time accessory printer generates report.

Rear Panel Controls :

• AC Circuit Breaker: Internal to AC power switch(1 for ON; 0 for OFF)

Rear Panel Inputs : 

• Inlet Filter: Intake for patient air; screw off cap for filter change
• External Battery: Connection for 12 VDC battery Communication Port: Calibration information during service procedure

SELLER: Meditech Electronics

Ventilator LP6

Product code (MPN): ITB-A5333EDC
Availability:In Stock
₹ 65000.00  Incl. GST ₹ 55084.75 Excl. GST
  • Description
    Our durable LP Series of portble volume ventilator have a repurarion for dependability. They are built with a patented brushes motor.

    Front Panel Controls :

    Mode: Standby, Assist/Control, SIMV or Pressure Cycle
    Low Pressure Alarm: Set limit for Low Pressure alarm 2 to 32
    cmH2O in increments of 2 cmH2O
    High Pressure Alarm Limit: (Assist/Control, SIMV Modes) or limit
    For Pressure Cycle mode: 15 to 90 cmH2O in increments of 5 cmH2O
    Volume: Push-to-turn knob: 100 to 2200 mL
    Breath Rate: 1 to 20 BPM in increments of 1 BPM and 22 to 38

    Inspiratory Time: 0.5 to1.0 sec in increments of 0.1 sec;
    1.2 sec; and 1.5 to 5.5 sec in increments of 0.5 sec
    Breathing Effort: Push-to-turn knob sets pressure level to detect
    breathing effort (-10 cmH2O/hPa to +10 cmH2O)


    Front Panel Input : 

    • Patient Pressure: Port for connection to proximal pressure line of patient circuit

    Front Panel Output :

    • Patient Air: 22 mm x 15 mm tube for connection to bacteria filter
    • Exhalation Valve: Port for connection to exhalation valve of patient circuit.

    Indicators, Normal Events :

    • Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can also display battery charge and machine hrs of operation
    • Breathing Effort: Green LED activated by adequate patient breathing effort
    • Power: LEDs indicate operating power source: green AC Pwr/Batt Chg, amber External Battery, flashing amber Internal Battery
    • Alarms: Flashing red LEDs: Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover.

    Audible Alarms :

    • Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, Setting Error, Power Switchover
    • Steady Tone: Loss of microprocessor control
    • Reminder Tone: Every 5 mins when powered by Internal Battery,each time accessory printer generates report.

    Rear Panel Controls :

    • AC Circuit Breaker: Internal to AC power switch(1 for ON; 0 for OFF)

    Rear Panel Inputs : 

    • Inlet Filter: Intake for patient air; screw off cap for filter change
    • External Battery: Connection for 12 VDC battery Communication Port: Calibration information during service procedure