Power Load (Three Phase Supply)
1 HP DC drive for machine roller.
1 HP AC motor for air blower.
4.0 KW (5.4 HP) heater.
Total load - 7.4 HP
Control Panel: In house electronic and electrical assemblies and DOL’s for blower’s etc. Each circuit will be provided with ELMCB for safety plus a heavy duty MCB for the mains.
Drive System: The machine will be provided with DC motor (Thyristor Controlled) coupled to heavy-duty reduction gearbox via chain and sprocket through the main shaft.
Heating System: Forced heated air through nozzles at the nips.
Utilities to be provided by Client: 4 Sq. mm 4 Core copper cable for main supply to the machines with proper earthling
Size of the Machine: Two in One Heat Sealing Machine 10 feet long for 1.8 meter fabrics
Output: 25 to 60 Mtr / Min at optimum speed either center or side sealing (Depending on operating Conditions)
Power Load (Three Phase Supply)
1 HP DC drive for machine roller.
1 HP AC motor for air blower.
4.0 KW (5.4 HP) heater.
Total load - 7.4 HP
Control Panel: In house electronic and electrical assemblies and DOL’s for blower’s etc. Each circuit will be provided with ELMCB for safety plus a heavy duty MCB for the mains.
Drive System: The machine will be provided with DC motor (Thyristor Controlled) coupled to heavy-duty reduction gearbox via chain and sprocket through the main shaft.
Heating System: Forced heated air through nozzles at the nips.
Utilities to be provided by Client: 4 Sq. mm 4 Core copper cable for main supply to the machines with proper earthling
Size of the Machine: Two in One Heat Sealing Machine 10 feet long for 1.8 meter fabrics
Output: 25 to 60 Mtr / Min at optimum speed either center or side sealing (Depending on operating Conditions)